Single-pack acrylic emulsion, bonding and curing agent

    durabond GP is a modified, single-pack acrylic emulsion which is milky in color.

    Uses:

    • As a primer/bonding medium for cementitious repairs to concrete elements in both internal and external applications.
    • Typically used with dura.rep GT, HS, FR and FS range of repair systems where normal or high build applications are required in vertical, horizontal or overhead locations.
    • durabond GP is an excellent curing compound for repairs carried out in both internal and external applications.
    • durabond GP is not suitable for repairs that will be subjected to continuous immersed conditions. For structural bonding, where the bond strength is to be equal or greater than the tensile strength of the parent concrete, use epidermix® 344 or 345.
    Advantages
    • Ease of application, single component product with a long open time.
    • Resistant to hydrolysis – alkali stable
    • Economical
    • Suitable for internal & external applications
    • One product – used as a bonding agent and curing compound
    • Bond strengths between repair mortar and concrete are excellent
    • Excellent curing properties
    • Compatible with our duracote® range of protective coatings
    • Non-toxic
    Surface Preparation

    The substrate must be clean, sound, and free of any oil, grease, loose particles, cement laitance and other contaminants. Should compressed air be employed, ensure that the air is clean and oil free. All edges to be repaired must be square-cut to a minimum of 10 mm deep, perpendicular to the surface, followed by the removal of all unsound material to a minimum depth as prescribed in the product selected for the repair. A sound exposed aggregate surface is recommended. Never feather edge the repair products. The substrate must be well dampened, with no free water on the surface prior to applying durabond GP.

    Coverage

    dura.bond GP applied as

    1. Priming/bonding agent: 4 – 6 m2/ℓ
    2. Curing compound: ± 5 m2/ℓ

    Note: Wastage and irregular surface profiles will reduce the practical coverage rates.

    Typical Physical Properties
    Type Liquid acrylic emulsion
    Colour Milky
    Minimum film forming  temperature (MFT) ±11° C
    Typical solids content ± 47%
    Density (typical) 1,060g/cm3
    pH value ±10
    Solvent resistance Not Resistant
    Water resistance Very High  (nevertheless do not use in permanent immersion applications)
    Freeze/thaw cycles Not stable
    Application

    For priming/bonding: 

    The prepared surface is to be thoroughly saturated using clean water prior to applying durabond GP. The surface saturation is generally carried out 1 to 2 hours before application but may require more depending on the substrate porosity, temperature and wind conditions. All excess free water must be removed. A saturated surface ensures ease of product spread and application, and reduces suction caused by porous substrates resulting in good bonding properties.

    durabond GP is applied to the surface, at the recommended application rate, using a stiff-bristle brush ensuring that the total area of repair is thoroughly coated. Care should be taken not to apply excessive amounts i.e. pooling and ponding must be avoided as this could result in the repair mortar ‘hogging’ or slipping on the surface, resulting in cracking and or poor adhesion.

    Immediately apply the repair mortar while the primed surface is still tacky and finish off accordingly. Should the durabond GP surface dry, then a second bond coat must be applied to receive the repair mortar. Drying may occur in 3 to 4 hours at 25°C but may vary subject to wind conditions.

    For curing the repair mortar durabond GP is applied by brush to the entire repaired area at the recommended coverage rate for optimum performance. The application must commence as soon as the surface will not be marred by brushing and have an unbroken film to provide a high curing efficiency. Note: For bonding and curing, durabond GP must be applied neat and must not be diluted. All equipment, paint trays or containers, must be clean.

    For curing the repair mortar durabond GP is applied by brush to the entire repaired area at the recommended coverage rate for optimum performance. The application must commence as soon as the surface will not be marred by brushing and have an unbroken film to provide a high curing efficiency. Note: For bonding and curing,  durabond GP must be applied neat and must not be diluted. All equipment, paint trays or containers, must be clean.

    Cleaning

    Clean tools and equipment with water before the material hardens.

    Protection on Completion

    In rapid drying conditions caused by high winds or direct sunlight additional precautions should be included, like sealing with polythene sheeting having the edges taped down. This may include damp hessian behind the sheeting to prevent moisture loss. Similarly in cold conditions, the repaired area must be protected from freezing. For additional protection properties, durabond GP is fully compatible with the duracote range of protective coatings and may be over coated as required.

    Temperature and Relative Humidity

    Surface and ambient temperature must be at least 5°C and growing, ideally between 20°C and 30ºC.

    Model Specification

    Acrylic bonding/curing agent for use with durarep repair mortars.

    The bonding agent will be durabond GP, an acrylic bonding and curing agent and will be applied in accordance with the recommendations of a.b.e.® Construction Chemicals.

    Packaging

    durabond GP is supplied in 25L plastic containers.

    Handling & Storage

    This product has a shelf life of 12 months if kept in a dry cool place in the original packaging. In more extreme conditions this period might be shortened. durabond GP must be protected from freezing during storage. Product which has been allowed to freeze at any stage must be discarded.

    Health & Safety

    Cured or wet durabond GP is non-toxic, non-flammable and slightly alkaline. Always wear gloves, eyewear and protective clothing when working with the material and avoid excessive inhalation, ingestion and skin contact. If material is splashed in the eye, wash off with clean water and seek medical attention.

    Important Note

    This data sheet is issued as a guide to the use of the product(s) concerned. Whilst a.b.e.® Construction Chemicals endeavors to ensure that any advice, recommendation, specification or information is accurate and correct, the company cannot – because a.b.e.® has no direct or continuous control over where and how a.b.e.® products are applied – accept any liability either directly or indirectly arising from the use of a.b.e.® products, whether or not in accordance with any advice, specification, recommendation, or information given by the company.

    Further Information

    Where other products are to be used in conjunction with this material, the relevant technical data sheets should be consulted to determine total
    requirements.

    a.b.e.® has a wealth of technical and practical experience built up over the years in the company’s pursuit of excellence in building and construction
    technology.